ICM – ICM292
Details
- Low cost form, fit and functional replacement for Rheem: 62-24140-04
- Direct Spark Ignition (DSI) control
- Microprocessor-based
- Controls inducer motors, air cleaner (if equipped), humidifier (if equipped), spark ignitor, and the gas valve
- Monitors timing, trial for ignition, system switches, flame sensing, and lockout
- 100-percent lockout safety feature
- Compatible with LP or Natural gas
- LED indication for status and fault codes to aid in troubleshooting
WEIGHT/DIMENSIONS:
- Weight: 0.6
- Height: 2.5
- Width: 6.625
- Length: 5.75
Specifications:
Control Voltage: 24 VAC (18-30 VAC), 60Hz
Line Voltage: 115 VAC, 60HzTiming: Pre-Purge: 30 seconds Trial for Ignition: 7 seconds Retries: Two groups of two, 30 second delay within the group, and 3 minute delay between groups Lockout: 1-hour Post-Purge: 90, 120, 160 and 180 secondsInputs: Power: 24 VAC and COM Thermostat Interface: R,W, Y, and G System Switches: Vent pressure and limit switches (main and over-temperature switches in series) Flame Sensing Heat Blower OFF Delay (miniature slide switch set)Outputs: Spark Gas Valve: GV Inducer Draft Motor: IDM Blower Motor: FAN, COOL and HEAT speeds Electric air Cleaner: EAC Humidifier Relay: HUM Heat/Cool Relay: H/CLED Indicators: Power, Green LED: PWR Status, Green LED: OK Flame Status, Yellow LED: FLAMEPatents: 6,222,719: Ignition Boost 5,917,691: Fail Safe Relay Driver